![]() | Residual current monitor, Type A IL 5882 • According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: IL 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880 - width 35 mm - for connection of external residual current transformer, e. g. DOLD ND 5016, ND5019 | Download datablad |
![]() | Residual current monitor, Type A SL 5882 • According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: SL 5882: 100 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts - width 35 mm - for connection of external residual current transformer, e. g. DOLD ND 5016, ND5019 | Download datablad |
![]() | Residual current monitor, Type A, with integrated transformer IR 5882 • According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • With sealable cover • Devices available in 3 enclosure versions: IR 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 88 - width 105 mm - with internal residual current transformer | Download datablad |
![]() | Residual current monitor, Type B RN 5883 • According to IEC/EN 62 020, VDE 0663 • For AC and DC systems Type B, according to IEC/TR 60755 • To detect earth faults in grounded voltage systems • 4 setting ranges from 10 mA to 3 A • Manual reset, with alarm and pre-warning • With adjustable switching delay • Energized or de-energized on trip • LED indicator for operation, pre-alarm and alarm • With test function • LED-chain indicates fault current • As option with analogue output • Broken wire detection • Protection against manipulation by sealable transparent cover over setting switches • Width: 52.5 mm | Download datablad |
![]() | Residual current monitor IP 5882.48 |
Du er her: Hjem > Produkter > E. Dold & Söhne – Danmark > Relæ Moduler > Overvågnings enheder > Fejlstrøms overvågning
Fejlstrøms overvågning
Unplanned interruptions of the operation of machines and systems are a significant cost factor. Insulation errors are a frequent cause for this. In grounded networks (TN networks), DOLD difference current sensors ensure reliable residual current monitoring. Expensive standstill time is avoided by this and, in addition, a possible risk of fire that latently exists by a gradual insulation error is also prevented. The difference current sensors are universally deployable as they can detect both direct and alternating current.