![]() | Interface module LG 3096 • With forcibly guided contacts according to IEC 61810-3 • Max. 6 contacts • As option goldplated contacts to switch low loads • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4 • As option with pluggable terminal blocks for easy exchange of devices - with screw terminals - or with cage clamp terminals • Width 22.5 mm | Download datablad |
![]() | Interface module MK 3096N • With forcibly guided contacts according to IEC 61810-3 • Max. 6 contacts • As option goldplated contacts to switch low loads • Wire connection: also 2 x 1.5 mm2 stranded ferruled, or 2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4 • As option with pluggable terminal blocks for easy exchange of devices - with screw terminals - or with cage clamp terminals • Width 22.5 mm | Download datablad |
![]() | Interface module UG 3096 • With forcibly guided contacts according to IEC 61810-3 • UG 3096: 8 output contacts UH 3096: 16 output contacts • As option with gold plated contacts to switch low loads • As option with contacts connected in series to switch high DC-loads • As option with pluggable terminal blocks for easy exchange of devices - with screw terminals • UG 3096: Width 22.5 mm UH 3096: Width 45 mm | Download datablad |
![]() | Interface module UH 3096 • With forcibly guided contacts according to IEC 61810-3 • UG 3096: 8 output contacts UH 3096: 16 output contacts • As option with gold plated contacts to switch low loads • As option with contacts connected in series to switch high DC-loads • As option with pluggable terminal blocks for easy exchange of devices - with screw terminals • UG 3096: Width 22.5 mm UH 3096: Width 45 mm | Download datablad |
![]() | Interface module UG 3088 • With forcibly guided contacts according to IEC 61810-3 • Version with up to 2 x 4 contacts • Variant to switch high DC-load • Width: 22,5 mm | Download datablad |
![]() | Interface module IK 3079 • According to IEC/EN 61 810-1 • With input protection circuit against voltage peaks • Forcibly guided contacts according to IEC 61810-3 • Ith max. 8 A or 2 x 5 A • Functional display by LED • Optionally 2 NO or 2 changeover contacts or 1 NO and 1 NC • IK 3079/103: with forcibly guided contacts according to ZH/457 • 17.5 mm width | Download datablad |
![]() | Interface module IP 3078 • According to IEC/EN 60 255, IEC/EN 61 810-1 • Forcibly guided contacts according to IEC 61810-3 • Max. 6 output contacts • High thermal current Ith = 8 A • LED for operating state • Devices available in 2 enclosure versions: IP 3078: depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880 SP 3078: depth 100 mm, with terminals at the top • Width 70 mm | Download datablad |
![]() | Interface module SP 3078 • According to IEC/EN 60 255, IEC/EN 61 810-1 • Forcibly guided contacts according to IEC 61810-3 • Max. 6 output contacts • High thermal current Ith = 8 A • LED for operating state • Devices available in 2 enclosure versions: IP 3078: depth 61 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880 SP 3078: depth 100 mm, with terminals at the top • Width 70 mm | Download datablad |
![]() | Interface module, with plug-type socket HC 3096N • According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1 • With forcibly guided contacts according to IEC 61810-3 • Models with soldered in or plug-in PCB safety relay consisting of: - plug in socket HC 3096N and safety relay OA 5611 - plug in socket HL 3096N and safety relay OA 5612 • With polarity protected diode • Optionally with free-wheeling diode across A1+ and A2 • Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au • For DIN rail mounting according IEC/EN 60715 • HC 3096N: width 18 mm HL 3096N: width 36 mm | Download datablad |
![]() | Interface module, with plug-type socket HL 3096N • According to DIN EN 61810-1, IEC 60664-1, IEC/EN 60 947-5-1 • With forcibly guided contacts according to IEC 61810-3 • Models with soldered in or plug-in PCB safety relay consisting of: - plug in socket HC 3096N and safety relay OA 5611 - plug in socket HL 3096N and safety relay OA 5612 • With polarity protected diode • Optionally with free-wheeling diode across A1+ and A2 • Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au • For DIN rail mounting according IEC/EN 60715 • HC 3096N: width 18 mm HL 3096N: width 36 mm | Download datablad |
![]() | Interface module HK 3087N • According to IEC/EN 61810-1, IEC 60664-1, • With forcibly guided contacts according to IEC 61810-3 • Models with soldered in PCB safety relay • With polarity protected diode • Optionally with free-wheeling diode across relay coil • With LED indicator • Optionally AgNi + 0,2 μm Au or AgNi + 5 μm Au • For DIN rail mounting according IEC/EN 60715 • Clearance and creepage distance between NC and NO contact > 10 mm • Width 22,5 mm | Download datablad |
![]() | Interface module, with plug-type socket HL 3094 • According to IEC/EN 60255, IEC/EN 61810-1 • With positively guided contacts according to EN 50 205 • Low nominal consumption: 0.75 W / 1 W / 1.25 W • Max. 8 output contacts • Contact material AgNi + 0.2 μm Au • High thermal current Ith = 8 A • Large temperature range: -25 ... +55°C • Safety relay soldered on board • Optionally AgNi + 5 μm Au or AgSnO + 0.2 μm Au • Optionally with free-wheeling diode across A1/A2 • Optionally plug-in type HA 5601 on socket HL 3094/10_ HA 5602 on socket HO 3094/10_ HA 5603on socket HO 3095/10_ • HL: 38 mm width HO: 73.3 mm width | Download datablad |
![]() | Interface module, with plug-type socket HO 3094 • According to IEC/EN 60255, IEC/EN 61810-1 • With positively guided contacts according to EN 50 205 • Low nominal consumption: 0.75 W / 1 W / 1.25 W • Max. 8 output contacts • Contact material AgNi + 0.2 μm Au • High thermal current Ith = 8 A • Large temperature range: -25 ... +55°C • Safety relay soldered on board • Optionally AgNi + 5 μm Au or AgSnO + 0.2 μm Au • Optionally with free-wheeling diode across A1/A2 • Optionally plug-in type HA 5601 on socket HL 3094/10_ HA 5602 on socket HO 3094/10_ HA 5603on socket HO 3095/10_ • HL: 38 mm width HO: 73.3 mm width | Download datablad |
![]() | Interface module, with plug-type socket HO 3095 • According to IEC/EN 60255, IEC/EN 61810-1 • With positively guided contacts according to EN 50 205 • Low nominal consumption: 0.75 W / 1 W / 1.25 W • Max. 8 output contacts • Contact material AgNi + 0.2 μm Au • High thermal current Ith = 8 A • Large temperature range: -25 ... +55°C • Safety relay soldered on board • Optionally AgNi + 5 μm Au or AgSnO + 0.2 μm Au • Optionally with free-wheeling diode across A1/A2 • Optionally plug-in type HA 5601 on socket HL 3094/10_ HA 5602 on socket HO 3094/10_ HA 5603on socket HO 3095/10_ • HL: 38 mm width HO: 73.3 mm width | Download datablad |
![]() | Interface module, with plug-type socket HC 3098 • According to DIN EN 61810 • With forcibly guided contacts according to IEC 61810-3 • Pluggable safety relay • Low rated power consumption: 0.8 W • Max. 2 output contacts • Contact material: AgNi with fine gold • High thermal current up to Ith = 5 A • Large temperature range: - 40 ... + 85 °C • As option with free-wheel diode or varistor between A1/A2 • As option with AgSnO2 or AgNi with hard gold • Width: 15.8 mm | Download datablad |
Du er her: Hjem > Produkter > E. Dold & Söhne – Danmark > Relæ Moduler > Sikkerheds Teknologi > Forsinkelse & Interface moduler > Interface moduler
Interface moduler
Coupling modules from DOLD are constructed with forcibly guided contacts a per EN 50205. The forcibly guided opener allows the monitoring of the closing contacts. As a ling between logic and load, they are used for the switching of safety-oriented functions. DOLD coupling modules are also used in the set up of self-monitoring safety switches. They are also the devices of choice for the adjustment of the control and power level as well as for the switching of safety-oriented functions.