Overvågnings relæer til bevægelige døre

Monitoring of movable safety door systems

DOLD offers you a wide spectrum of safety door monitoring modules for a wide variety of applications. The ready-to-connect switching devices mounted on DIN rails monitor the position of movable safety door devices. They can be used anywhere where entry and/or access to a room with dangerous movements makes protection necessary, e.g. for the operation of the machine, the configuration or troubleshooting. The safety door monitoring modules monitor the position of movable safety door switches that are actuated by the opening and/or closing of the safety device.
Emergency stop module / safety gate monitor BG 5925/920
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• to connect:
- magnetic switch NE 5020
- magnetic switch NE 5021
• Output: max. 3 NO contacts, see contacts
• 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• Cross fault monitoring
• LED indicator for state of operation
• LED indicator for channel 1 and 2
• Optionally with fast Auto start
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 22.5 mm
Download datablad
Emergency stop module with delay up to 600s / Safety gate monitor BO 5988.47
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V
• 1-channel or 2-channel connection
• Line fault detection at On pushbutton
• Feedback circuit X1-X2 for monitoring external contactors
• Integrated short-circuit and overvoltage protection
• LED displays for channels 1 and 2 and supply
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Optionally with release delayed NO contact to 10 min
• Optionally automatic On function after connection of operating voltage
or activation via On pushbutton
• Optionally cross fault detection in emergency stop control circuit
• Optionally dual voltage version
• Width 100 mm
Download datablad
Emergency stop module / safety gate monitor BO 5988.61
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: max. 6 NO, 1 NC contacts or 1 NO contact for AC 250 V
• 1-channel or 2-channel connection
• Line fault detection at On pushbutton
• Feedback circuit X1-X2 for monitoring external contactors
• Integrated short-circuit and overvoltage protection
• LED displays for channels 1 and 2 and supply
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Optionally with release delayed NO contact to 10 min
• Optionally automatic On function after connection of operating voltage
or activation via On pushbutton
• Optionally cross fault detection in emergency stop control circuit
• Optionally dual voltage version
• Width 100 mm
Download datablad
Switch gear for safety switch LG 5925/920
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• to connect:
- safety switch NE 5020
- safety switch NE 5021
• Output: max. 4 NO contacts, see contacts
• 1- or 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• with or without cross fault monitoring switch S1
• LED indicator for state of operation
• LED indicator for channel 1 and 2
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with plugable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width 22.5 mm
Download datablad
Emergency stop module UF 6925
• According to
-- Performance Level (PL) e and category 4 to EN ISO 13849-1
-- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
-- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-1 for furnaces
• 2-channel operation
• Forcibly guided output contacts
• With or without cross fault monitoring in the E-stop loop, switch S1
• Manual restart or automatic restart, switch S2
• LED indicator for channel 1, 2 and Netz
• Width 17,5 mm
Download datablad
Emergency stop module LG 5925
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• According to EN 50156-2 for furnaces
• Output: max. 4 NO contacts, see contacts
• LG 5925.54: 1 semiconductor output
• Single and 2-channel operation
• Line fault detection on On-button
• Manual restart or automatic restart, switch S2
• With or without cross fault monitoring in the E-stop loop, switch S1
• LG 5925.54: with cross fault monitoring in the E-stop loop
• LED indicator for state of operation
• LED indicator for channel 1 and 2
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled, or
2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4
• As option with pluggable terminal blocks for easy exchange
of devices
- with screw terminals
- or with cage clamp terminals
• Width: 22.5 mm
Download datablad
Emergency stop module BD 5987
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 2 NO contacts for AC 250 V
• 1-channel or 2-channel connection
• LED displays for channels 1 and 2
• Overvoltage and short circuit protection
• Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width 45 mm

BD 5987._ _/001: same as BD 5987._ _ but
• Optionally automatic On function or after activation by the On pushbutton
• Optionally cross fault detection in emergency stop circuit

BD 5987.02/301: same as BD 5987.02/001 but
• Suitable also for elevators according to EN 81-1/-2
• Complies to the requirements of the directive 95/16/EG for elevators
• According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
• Shorter release time when opening the supply circuit
• Single-channel e-stop circuit
Download datablad
Emergency stop module BN 5983Download datablad
Emergency stop module BD 5935
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
• 1- or 2-channel connection
• Operating state display
• LED display for channels 1 and 2
• Overvoltage and short circuit protection
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Output: optionally 1 NO / 1 NC or 3 NO / 1 NC contacts
• Optionally automatic ON function or activation via the ON pushbutton
• With fast auto start as option
• Width 45 mm
Download datablad
Emergency stop module with delay up to 300s BH/BI 5928
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508 and IEC/EN 61511
• Output: 3 NO or 2 NO, 1 NC instantaneous contacts and
3 NO release delayed contacts
• Single and 2-channel operation
• Line fault detection on On-button,
when On-button is connected to S33-S34
• Manual restart with button on S33-S34 or automatic restart with
bridge between S13-S14
• With or without cross fault monitoring in the E-stop loop
• LED indication for supply, channel 1/2 and release delayed contacts
• Removable terminal strips
• Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• Width
BH 5928: 45 mm
BI 5928: 67.5 mm
Download datablad
Emergency stop module BN 5930.48/203 & 204
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Category 4 to EN 954-1
• BN 5930.48/203 with cross fault detection by connecting
2 different phases, max. 400 V,
BN 5930.48/204 with cross fault detection by connecting
phase and neutral, max. 230 V
• Dual voltage version
• Emergency-stop circuit T12, T22:
optionally for AC 110 V / DC 60 V or AC 230 V / DC 110 V
• Output: 3 NO, 1 NC contacts for AC 400 V
• 1-channel or 2-channel circuit
• LED displays for channel 1, 2 and mains
• Feedback circuit X1 - X2 for monitoring external contactors
• Removable terminal strips
• Width 100 mm